Please note that not all doors are approved in every wall type so please discuss your particular requirements with your local licensed pyropanel.
Fire rated door frames in plasterboard walls.
Supplied with a three way locking system and metal key.
Approved wall types include.
Supplied with a three way locking system and metal key.
Double layer 12 5mm gyproc fireline each side of gypframe 48 s 50 studs provides 120 minutes.
Fast delivery australia wide.
The gyprock range of fire resistant plasterboard includes.
These requirements apply to all fire rated doors frames and windows.
These access panels have been successfully tested to give up to 1 hour integrity in a ceiling system and 2 hours for a wall system.
Fire rated loft hatch access panel for wall or ceiling with plasterboard door and concealed beaded perforated frame.
The metal perforated frame is designed to be plastered over as well as the door leaving a neat clean finish.
Zinc galvanised or stainless steel fire door frames with steel thickness options available.
Compliance frame tags included with every frame.
Consult with individual fire door frame manufacturers listings for fire door frames that can be used in drywall stud walls with a maximum 3 hour.
Double layer 15mm gyproc wallboard each side of gypframe 48 s 50 studs provides 90 minutes.
Fire rated up to 2 hours integrity.
Masonry steel and timber stud plaster board boral intrwall shaftliner systems speedpanel walls hebel walls and concrete blocks.
When a fire door frame is built into a plasterboard wall it should be backfilled with fire rated plasterboard strips prior to installing into the wall.
Fire door frames frames used in masonry walls may be used with a maximum 3 hour fire door while frames used in drywall stud walls are intended to be used with a maximum 1 1 2 hour fire door.
Door and frame fully polyester powder coated ral 9010 20 gloss.
Door and frame fully polyester powder coated ral 9010 20 gloss.
Custom made fire door frames to suit new build cast in fire door frames or existing wall retro fit fire door frames.
200mm thick plaster walls stud clip fixing fire door frame.
To suit door thickness to suit door thickness 1 5 8 min 4 5 8 max 5 8 min 1 min 2 or 3 min 13 max 1 4 min 1 min 4 max 1 max.
Fyrchek fyrchek mr ec08 impact ec08 impact mr and ec08 complete.
As you can see by varying the type of board and number of layers any of the commonly encountered fire resistance durations can be met.
Unfortunately it is not possible to fill frames in plaster walls post installation.
Fire rated wall access panel or ceiling access panel with plasterboard door and concealed beaded perforated frame.
All frames should be built in true and square and all frames must be sealed back to the fire rated wall using pyropanel multiflex fire rated acrylic sealant see passive product range.
Each of these products can be used to enhance the fire performance of walls and ceilings in areas such as kitchens school laboratories and specialist applications where the risk of fire is a concern.