If venting outside isn t an option you can vent the dryer out of the attic through the roof using a special roof vent to keep rain out.
Dryer vent through roof.
If your laundry room has access to an outside wall cut a hole and install a standard dryer vent.
Difficulty cleaning dryer vent.
Check with your appliance dealer or local building inspector for recommendations about the best roof vent cap to use.
I think the roof is a stupid spot to terminate clothes dryer vents because it s difficult to clean and it s a major contributor to ice dams.
A vertical dryer vent is typically a problem because it acts as a moisture condenser.
Considering that back pressure higher than 6 wci is generally recognized as inefficient you can see that venting through the roof with non dryer specific vents is immediately problematic.
The sheet metal duct is cooled by the outside air in the attic.
Then get on the roof and peel back any shingles that may be covering the vent as well as the guard.
Vent a dryer through the roof only as a last resort.
The vent should exit the building through the roof or wall at least 3 feet away from any other building openings and the vent cover which must not include a screen should allow dispersal of.
Cleaning lint buildup from roof vents is difficult and nesting birds and squirrels often find roof vent caps irresistible.
Be careful you don t cut through any studs electrical wires or pipes in the process.
Clothes dryers should be vented through the side of the house preferably within reach from the ground.
Before you clean a dryer vent on the roof vacuum out the vent behind the dryer since it s easier to clean out the length of the vent from the ground floor.
As soon as i m in charge there will be no more venting of clothes dryers through the roof.
The less back pressure is created by the roof vent the more efficiently the system performs.
Once the vent is exposed use a vent brush first clean the exterior surfaces.
These terminals need to be cleaned on a regular basis to prevent lint buildup.
Dryer vents should always be vented through the side of the house and not vented through the roof and ideally the exit should be fairly close to the ground.